Carbon dioxide concentration detector is an explosion-proof carbon dioxide gas detector developed and produced by our company according to industrial grade design standards, which can be directly installed in hazardous areas of Zone 1 and Zone 2; aluminum alloy explosion-proof housing, durable; support 24-hour continuous online monitoring; 12-30V wide voltage DC power supply; RS485 signal output, supporting long-distance data telemetry; built-in imported brand Carbon dioxide gas sensor probe, high precision, strong stability, low error rate; full range temperature compensation, to ensure long-term stability and reliability of the measurement value; comes with automatic correction function of the zero point in the air, to ensure that the product does not appear false alarm phenomenon in the process of use.
This carbon dioxide concentration detector has excellent performance, high stability and easy installation and maintenance, which greatly meets the requirements of industrial site safety monitoring for high reliability of equipment, and is widely used in various places such as indoor chemical product workshops (chemical plants, pharmaceutical plants), chemical product and pharmaceutical warehouses, cable and cosmetic plants, food plants, wineries, laboratories, coal mines, substations, etc.
Operating Voltage |
24 VDC |
Measurement Range |
0~5000ppm |
Resolution |
1ppm |
Linearity error |
≤±2% |
Gas extraction method |
Natural diffusion type |
Design life |
2 to 5 years |
Transmission method |
RS485, Modbus RTU |
Operating temperature |
0℃~+50℃ |
Working humidity |
10~95%RH |
Work stress |
86~106Kpa |
Design Standards |
GB 50493-2009 "Design Specification for Detection and Alarm of Combustible and Toxic Gases in Petrochemical Enterprises |
Implementation Standards |
GB3836.1-2010《Electrical Equipment for Explosive Gas Environments Part I: General Requirements》
GB12358-2006 《Workplace environmental gas detection alarm General technical requirements》 GB 12476.1-2013 Electrical equipment for combustible dust environment Part 1: General requirements GB 12476.1-2013 Electrical equipment for combustible dust environments Part 5: Enclosure protection type "tD" |
Explosion-proof grade |
Exd IICT6 Gb/Ex tD A21 IP66 T80℃ |
Protection level |
IP66 |
Product Center
Sensing terminalsData Acquisition (DAQ) and ControlPlatform SoftwareSmart Thermal PowerSmart CitySmart GridSmart IOTIntelligent inspectionSmart FactorySolutions
Intelligent rail robot substation appl... Intelligent rail inspection robot in c... Intelligent track inspection robot Ap... Orbital inspection robot in the appli... Functional application of unattended ... Unattended bucket wheel system Enclosed Coal Yard Safety Monitoring System Laser Disc Coal System Temperature measuring infrared thermal imagerContact Us